skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Test procedure for measurement of performance vs temperature of Whittaker electrochemical cell

Technical Report ·
DOI:https://doi.org/10.2172/325412· OSTI ID:325412

This document is the test procedure to systematically test the Whittaker cells between the temperatures of -20 degrees F and +120 degrees F. These sensors are used on the Rotary Mode Core Sampling (RMCS) flammable gas interlock (FGI), to detect and quantify hydrogen gas. This procedure supports the testing, that is being performed after cold weather attempts on the Whittaker cell failed.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
325412
Report Number(s):
HNF-SD-WM-TC-072; ON: DE98059521; BR: EW3120074; TRN: 97000052
Resource Relation:
Other Information: PBD: 23 Jan 1997
Country of Publication:
United States
Language:
English