Consequences of a radioactive surface pool resulting from waste transfer operations between tanks 214-C-106 and 241-AY-102
This document contains supporting calculations for quantifying the dose consequences from a pool formed from an underground leak or a-leak from an above grade structure for the Waste Retrieval Sluicing System (Project W-320), i.e., sluicing the contents of Tank 241-C-106 (high heat, SST) into Tank 241-AY-102 (aging waste, DST).
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 313339
- Report Number(s):
- HNF-SD-WM-CN-110; ON: DE99050122; BR: EW3120071; TRN: 99:003013
- Resource Relation:
- Other Information: PBD: 5 Aug 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Nonradioactive air emissions notice of construction, Project W-320, 241-C-106 tank sluicing
Review of Waste Retrieval Sluicing System Operations and Data for Tanks 241-C-106 and 241-AY-102
Radiological and toxicological analyses of tank 241-AY-102 and tank 241-C-106 ventilation systems
Technical Report
·
Wed Jan 28 00:00:00 EST 1998
·
OSTI ID:313339
Review of Waste Retrieval Sluicing System Operations and Data for Tanks 241-C-106 and 241-AY-102
Technical Report
·
Tue Sep 26 00:00:00 EDT 2000
·
OSTI ID:313339
+4 more
Radiological and toxicological analyses of tank 241-AY-102 and tank 241-C-106 ventilation systems
Technical Report
·
Tue Aug 11 00:00:00 EDT 1998
·
OSTI ID:313339