Tank 241-C-106 sluicing evaluation
The Process Engineering Analyses group performed a Thermal evaluation of the Project W-320 retrieval process. The objective of this study was to characterize the thermal response of the tank 241-C-106 waste during the sluicing operation and to define operating limits (defined with measurable tank data), which will maintain the waste subcooling required by the operational controls.