Title: Calculation of SY tank annulus continuous air monitor readings after postulated leak scenarios

Technical Report ·
DOI:https://doi.org/10.2172/290875· OSTI ID:290875

The objective of this work was to determine whether or not a continuous air monitor (CAM) monitoring the annulus of one of the SY Tanks would be expected to alarm after three postulated leak scenarios. Using data and references provided by Lockheed Martin`s Tank Farm personnel, estimated CAM readings were calculated at specific times after the postulated scenarios might have occurred. Potential CAM readings above background at different times were calculated for the following leak scenarios: Leak rate of 0.01 gal/min; Leak rate of 0.03 gal/min (best estimate of the maximum probable leak rate from a single-shell tank); and Leak of 73 gal (equivalent to a {1/4}-in. leak on the floor of the annulus). The equation used to make the calculations along with descriptions and/or explanations of the terms are included, as is a list of the assumptions and/or values used for the calculations.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Civilian Radioactive Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
290875
Report Number(s):
PNNL-11956; R&D Project: N/A; ON: DE98058039; BR: N/A; TRN: 99:002116
Resource Relation:
Other Information: PBD: Aug 1998
Country of Publication:
United States
Language:
English

Similar Records

In Shop Acceptance Test Report for the SY Farm Annulus Leak Detectors
Technical Report · Tue Dec 07 00:00:00 EST 1999 · OSTI ID:290875

Test Plan for New SY Farm Annulus Leak Detectors
Technical Report · Fri Aug 13 00:00:00 EDT 1999 · OSTI ID:290875

Engineering task plan for the new SY farm annulus leak detectors
Technical Report · Tue Jun 01 00:00:00 EDT 1999 · OSTI ID:290875