skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: An evaluation of alternative cleaning methods for removing an organic contaminant from a stainless steel part

Technical Report ·
DOI:https://doi.org/10.2172/285494· OSTI ID:285494

As of December 1995, the manufacture of Freon, along with many other chlorofluorocarbons (CFCs), was prohibited by the Clean Air Act of 1990 (CAA). The ban of CFC solvents has forced manufacturers across the country to search for alternative metal cleaning techniques. The objective of this study was to develop a thorough, scientific based approach for resolving one specific manufacturer`s problem of removing organic contamination from a stainless steel part. This objective was accomplished with an approach that involved: (1) defining the problem, (2) identifying the process constraints, (3) researching alternate cleaning methods, (4) researching applicable government regulations, (5) performing a scientific evaluation and (6) drawing conclusions.

Research Organization:
Bettis Atomic Power Lab., West Mifflin, PA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC11-93PN38195
OSTI ID:
285494
Report Number(s):
WAPD-T-3103; ON: DE96012821; TRN: 96:005020
Resource Relation:
Other Information: PBD: [1996]
Country of Publication:
United States
Language:
English