Title: Preliminary design requirements document (DRD) for Project W-236B, ``Initial Pretreatment Module``

Technical Report ·
DOI:https://doi.org/10.2172/28243· OSTI ID:28243

The scope of this Design Requirements Document (DRD) is to identify and define the functions, with associated requirements, which must be performed to separate Hanford Site tank waste supernatants into low-level and high-level fractions. This documents sets forth function requirements, performance requirements, and design constraints necessary to begin conceptual design for the Initial Pretreatment Module (IPM). System and physical interfaces between the IPM project and the Tank Waste Remediation System (TWRS) are identified. The constraints, performance requirements, and transfer of information and data across a technical interface will be documented in an Interface Control Document. Supplemental DRDs will be prepared to provide more detailed requirements specific to systems described in the DRD.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
28243
Report Number(s):
WHC-SD-W236B-DRD-001; ON: DE95007789; TRN: 95:008885
Resource Relation:
Other Information: PBD: 15 Feb 1995