Analysis of trapped gas in 1E34 detonators by gas chromatography
A method was developed to extract and then analyze gas trapped in thermally aged 1E34 detonators. This gas was extracted into an evacuated volume and injected into a gas chromatograph for separation and quantitative analysis. To effect this gas extraction, a device was designed for puncturing the detonator cup and capturing the effused gas. Limited testing of five detonators in this device shows amounts of gas ranging from about 0.5 X 10 {sup -7} to 12 X 10 {sup - 7} moles.