skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effect of repository underground ventilation on emplacement drift temperature control

Conference ·
OSTI ID:212421
; ; ;  [1]
  1. Morrison Knudson Corporation, Las Vegas, NV (United States)

The repository advanced conceptual design (ACD) is being conducted by the Civilian Radioactive Waste Management System, Management & Operating Contractor. Underground ventilation analyses during ACD have resulted in preliminary ventilation concepts and design methodologies. This paper discusses one of the recent evaluations -- effects of ventilation on emplacement drift temperature management.

Research Organization:
TRW, Inc., Fairfax, VA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC01-91RW00134
OSTI ID:
212421
Report Number(s):
CONF-960421-20; ON: DE96007390; TRN: 96:020691
Resource Relation:
Conference: 7. annual international high-level radioactive waste management conference, Las Vegas, NV (United States), 29 Apr - 3 May 1996; Other Information: PBD: [1996]
Country of Publication:
United States
Language:
English