Radionuclide content of simulated and fully radioactive SRLLL waste gl;asses: comparison of results from ICP-MS, gamma spectrometry and alpha spectrometry
Conference
·
OSTI ID:211466
We have measured the transuranic content of two transuranic=doped, simulated waste glasses, using inductively coupled plasma-mass spectrometry (ICP-MS), {gamma}-spectrometry, and {alpha}-spectrometry. Average concentrations measured by each technique were within {+-} 10% of the as-doped concentrations. We also report the transuranic content of three fully radioactive SRL waste glasses that were determined using {gamma}- and {alpha}-spectrometry measurements to deconvolute isobaric interferences present in the ICP-MS analyses.
- Research Organization:
- Argonne National Lab. (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31-109-ENG-38
- OSTI ID:
- 211466
- Report Number(s):
- ANL/CMT/CP-86907; CONF-951155-67; ON: DE96007218; TRN: 96:012125
- Resource Relation:
- Conference: Fall meeting of the Materials Research Society (MRS), Boston, MA (United States), 27 Nov - 1 Dec 1995; Other Information: PBD: [1995]
- Country of Publication:
- United States
- Language:
- English
Similar Records
Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)
Actinides at the crossroads: ICP-MS or alpha spectrometry?
Flow injection sample pretreatment for the determination of radionuclides in soils by ICP-MS
Conference
·
Mon Jul 01 00:00:00 EDT 2013
·
OSTI ID:211466
+1 more
Actinides at the crossroads: ICP-MS or alpha spectrometry?
Conference
·
Sun Dec 31 00:00:00 EST 1995
·
OSTI ID:211466
+4 more
Flow injection sample pretreatment for the determination of radionuclides in soils by ICP-MS
Conference
·
Sat Dec 31 00:00:00 EST 1994
·
OSTI ID:211466