skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Pooling techniques for bioassay screening

Conference ·
OSTI ID:206612

Pooling techniques commonly are used to increase the throughput of samples used for screening purposes. While the advantages of such techniques are increased analytical efficiency and cost savings, the sensitivity of measurements decreases because it is inversely proportional to the number of samples in the pools. Consequently, uncertainties in estimates of dose and risk which are based on the results of pooled samples increase as the number of samples in the pools increases in all applications. However, sensitivities may not be seriously degraded, for example, in urinalysis, if the samples in the pools are of known time duration, or if the fraction of some attribute of the grab urine samples to that in a 24-hour composite is known (e.g., mass, specific gravity, creatinine, or volume, per 24-h interval). This paper presents square and cube pooling schemes that greatly increase throughput and can considerably reduce analytical costs (on a sample basis). The benefit-cost ratios for 5{times}5 square and 5{times}5{times}5 cube pooling schemes are 2.5 and 8.3, respectively. Three-dimensional and higher arrayed pooling schemes would result in even greater economies; however, significant improvements in analytical sensitivity are required to achieve these advantages. These are various other considerations for designing a pooling scheme, where the number of dimensions and of samples in the optimum array are influenced by: (1) the minimal detectable amount (MDA) of the analytical processes, (2) the screening dose-rate requirements, (3) the maximum masses or volumes of the composite samples that can be analyzed, (4) the information already available from results of composite analysis, and (5) the ability of an analytical system to guard against both false negative and false positive results. Many of these are beyond the scope of this paper but are being evaluated.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
206612
Report Number(s):
BNL-62141; CONF-960409-1; ON: DE96008215
Resource Relation:
Conference: 9. international congress on radiation protection and general assembly of the International Radiation Protection Association (IRPA), Vienna (Austria), 14-19 Apr 1996; Other Information: PBD: [1996]
Country of Publication:
United States
Language:
English