The operation of plastic MSGCs at high rates
Conference
·
OSTI ID:192536
- and others
The operation of MicroStrip Gas Counters (MSGCS) on a Upilex (polyimide) substrate is described. The surface resistivity of the substrate was reduced by ion implantation or by coating with a thin film of nickel oxide. Results are presented concerning the surface resistivity and The lowering of the substrate resistivity allows perate at very high rates and several devices in a high flux X-ray beam. Substrates with optimum resistivity showed no gain changes whereas gain changes were seen on those with higher resistivity.