NuMI proton kicker extraction system
This system extracts up to 9.6 {micro}s of 120 GeV beam every 1.87 seconds for the NuMI beamline neutrino experiments. A pulse forming network consisting of two continuous wound coils and 68 capacitors was designed and built to drive three kicker magnets. The field stability requirement is better than {+-} 1% with a field rise time of 1.52 {micro}s. New kicker magnets were built based on the successful traveling wave magnets built for the Main Injector. Two of these magnets are in series which places a serious constraint on the rise time of the pulser. A forced cooling system using Fluorinert{reg_sign} was designed for the magnet termination resistors to maintain the field flatness and amplitude stability.