Title: Recent Flash X-Ray Injector Modeling

Technical Report ·
DOI:https://doi.org/10.2172/15015137· OSTI ID:15015137

The injector of the Flash X-Ray (FXR) accelerator has a significantly larger than expected beam emittance. A computer modeling effort involving three different injector design codes was undertaken to characterize the FXR injector and determine the cause of the large emittance. There were some variations between the codes, but in general the simulations were consistent and pointed towards a much smaller normalized, rms emittance (36 cm-mr) than what was measured (193 cm-mr) at the exit of the injector using a pepperpot technique. The simulations also indicated that the present diode design was robust with respect to perturbations to the nominal design. Easily detected mechanical alignment/position errors and magnet errors did not lead to appreciable increase in the simulated emittance. The physics of electron emission was not modeled by any of the codes and could be the source of increased emittance. The nominal simulation assumed uniform Child-Langmuir Law emission from the velvet cathode and no shroud emission. Simulations that looked at extreme non-uniform cathode and shroud emission scenarios resulted in doubling of the emittance. An alternative approach was to question the pepperpot measurement. Simulations of the measurement showed that the pepperpot aperture foil could double the emittance with respect to the non-disturbed beam. This leads to a diplomatic explanation of the discrepancy between predicted and measured emittance where the fault is shared. The measured value is too high due to the effect of the diagnostic on the beam and the simulations are too low because of unaccounted cathode and/or shroud emission physics. Fortunately there is a relatively simple experiment that can resolve the emittance discrepancy. If the large measured emittance value is correct, the beam envelope is emittance dominated at modest values of focusing field and beam radius. Measurements of the beam envelope on an imaging foil at the exit of the injector would lead to an accurate value of the emittance. If the emittance was approximately half of the measured value, the beam envelope is slightly space charge dominated, but envelope measurements would set reasonable bounds on the emittance value. For an emittance much less than 100 cm-mr, the envelope measurements would be insensitive to emittance. The outcome of this envelope experiment determines if a redesigned diode is needed or if more sophisticated emittance measurements should be pursued.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
15015137
Report Number(s):
UCRL-TR-208574; TRN: US0501553
Resource Relation:
Other Information: PBD: 10 Nov 2004
Country of Publication:
United States
Language:
English