ICPP water inventory study progress report
Recent data from the Idaho Chemical Processing Plant (ICPP) indicate that water is entering the sumps located in the bottom of Tank Firm Vaults in quantities that exceed expected levels. In addition, perched water body(s) exist beneath the northern portion of the ICPP. Questions have been raised concerning the origin of water entering the Tank Farm sumps and the recharge sources for the perched water bodies. Therefore, in an effort to determine the source of water, a project has been initiated to identify the source of water for Tank Farm sumps and the perched water bodies. In addition, an accurate water balance for the ICPP will be developed. The purpose of this report is to present the specific results and conclusions for the ICPP water balance portion of the study. In addition, the status of the other activities being conducted as part of study, along with the associated action plans, is provided.
- Research Organization:
- Westinghouse Idaho Nuclear Co., Inc., Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC07-84ID12435
- OSTI ID:
- 142566
- Report Number(s):
- WINCO-1184; ON: DE94008922; TRN: 94:006608
- Resource Relation:
- Other Information: PBD: May 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
ICPP water inventory study leak test report
Analysis of ICPP tank farm infiltration