Title: Reservoir response to thermal and high-pressure well stimulation efforts at Raft River, Idaho

Conference ·
OSTI ID:1363925
 [1];  [2];  [2];  [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
  2. Energy & Geoscience Institute at the Univ. of Utah, Salt Lake City, UT (United States)

An injection stimulation test begun at the Raft River geothermal reservoir in June, 2013 has produced a wealth of data describing well and reservoir response via high-resolution temperature logging and distributed temperature sensing, seismic monitoring, periodic borehole televiewer logging, periodic stepped flow rate tests and tracer injections before and after stimulation efforts. One of the primary measures of response to the stimulation is the relationship between fluid pressure and flow rate, short-term during forced flow rate changes and the long-term change in injectivity. In this paper we examine that hydraulic response using standard pumping test analysis methods, largely because pressure response to the stimulation was not detected, or measurable, in other wells. Analysis of stepped rate flow tests supports the inference from other data that a large fracture, with a radial extent of one to several meters, intersects the well in the target reservoir, suggests that the flow regime is radial to a distance of only several meters and demonstrates that the pressure build-up cone reaches an effective constant head at that distance. The well’s longer term hydraulic response demonstrated continually increasing injectivity but at a dramatically faster rate later from ~2 years out and continuing to the present. The net change in injectivity is significantly greater than observed in other longterm injectivity monitoring studies, with an approximately 150–fold increase occurring over ~2.5 years. While gradually increasing injectivity is a likely consequence of slow migration of a cooling front, and consequent dilation of fractures, the steady, ongoing, rate of increase is contrary to what would be expected in a radial or linear flow regime, where the cooling front would slow with time. As a result, occasional step-like changes in injectivity, immediately following high-flow rate tests suggest that hydro shearing during high-pressure testing altered the near-well permeability structure.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE)
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1363925
Report Number(s):
INL/CON-16-39543
Resource Relation:
Conference: 40. Workshop on Geothermal Reservoir Engineering, Stanford, CA (United States), 26-28 Jan 2015
Country of Publication:
United States
Language:
English

Similar Records

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing
Conference · Fri Jan 01 00:00:00 EST 2021 · Stanford Geothermal Workshop · OSTI ID:1363925

Reservoir Response to Thermal and High-Pressure Well Stimulation Efforts at Raft River, Idaho
Conference · Mon Jan 26 00:00:00 EST 2015 · Stanford Geothermal Workshop · OSTI ID:1363925

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site