Title: Instrumentation Cables Test Plan

Technical Report ·
DOI:https://doi.org/10.2172/1330613· OSTI ID:1330613
 [1];  [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift and fluctuate, while the thermoplastic insulated cables, the instrument reading fell off-scale rapidly. From an operational point of view, the latter failure characteristics would likely be identified as a failure from the effects of fire, while the former may result in inaccurate readings.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1330613
Report Number(s):
SAND2016-10803R; 648617
Country of Publication:
United States
Language:
English

Similar Records

Fire protection of safe shutdown capability at commercial nuclear power plants
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:1330613

Post-Fire Safe Shutdown Capability. An Inspector's Handbook. Draft Report
Technical Report · Wed Feb 01 00:00:00 EST 2017 · OSTI ID:1330613

Browns Ferry nuclear power-plant fire on March 22, 1975
Journal Article · Thu Jan 01 00:00:00 EST 1976 · Nucl. Saf.; (United States) · OSTI ID:1330613