Title: Strategy for alignment of electron beam trajectory in LEReC cooling section

Technical Report ·
DOI:https://doi.org/10.2172/1329782· OSTI ID:1329782

We considered the steps required to align the electron beam trajectory through the LEReC cooling section. We devised a detailed procedure for the beam-based alignment of the cooling section solenoids. We showed that it is critical to have an individual control of each CS solenoid current. Finally, we modeled the alignment procedure and showed that with two BPM fitting the solenoid shift can be measured with 40 um accuracy and the solenoid inclination can be measured with 30 urad accuracy. These accuracies are well within the tolerances of the cooling section solenoid alignment.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP)
DOE Contract Number:
SC00112704
OSTI ID:
1329782
Report Number(s):
BNL-112720-2016-IR; R&D Project: KBCH139; KB0202011; TRN: US1700405
Country of Publication:
United States
Language:
English