Title: System Study: High-Pressure Core Spray 1998-2014

Technical Report ·
DOI:https://doi.org/10.2172/1261235· OSTI ID:1261235
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States). Risk Assessment and Management Services Dept.

This report presents an unreliability evaluation of the high-pressure core spray (HPCS) at eight U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCS results.