This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago—a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area, in which high heating energy use typical in these buildings threaten housing affordability, and uninsulated mass masonry wall assemblies are uncomfortable for residents. In this project, the Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by DOE to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

Authors:
 [1]
  1. Building Science Corporation, Somerville, MA (United States)
Publication Date:
Research Org.:
Building Science Corporation, Somerville, MA (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
OSTI Identifier:
1220231
Report Number(s):
DOE/GO-102013-3904
6470
DOE Contract Number:  
AC36-08GO28308; KNDJ-0-40337-02
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
exterior insulation; exterior insulation retrofit; masonry retrofit; brick retrofit; overclad; masonry over-clad; high performance retrofit; Chicago; CEDA; Weatherization; brick masonry retrofit; brick masonry; brick masonry retrofit strategy residential; residential building; Building Science Corporation (BSC); Building America

Citation Formats

Neuhauser, Ken. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago. United States: N. p., 2013. Web. doi:10.2172/1220231.
Neuhauser, Ken. Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago. United States. https://doi.org/10.2172/1220231
Neuhauser, Ken. 2013. "Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago". United States. https://doi.org/10.2172/1220231. https://www.osti.gov/servlets/purl/1220231.
@article{osti_1220231,
title = {Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago},
author = {Neuhauser, Ken},
abstractNote = {This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago—a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area, in which high heating energy use typical in these buildings threaten housing affordability, and uninsulated mass masonry wall assemblies are uncomfortable for residents. In this project, the Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by DOE to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.},
doi = {10.2172/1220231},
url = {https://www.osti.gov/biblio/1220231}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Aug 01 00:00:00 EDT 2013},
month = {Thu Aug 01 00:00:00 EDT 2013}
}