Title: Long-Term Results. New Construction Occupied Test House, Urbana, Illinois

Technical Report ·
DOI:https://doi.org/10.2172/1219800· OSTI ID:1219800
 [1];  [1]
  1. IBACOS, Inc., Pittsburgh, PA (United States)

For this study, a house was designed and built to the Passive House (Passivhaus) Standard for low energy consumption. The house incorporates an airtight, super-insulated thermal enclosure, southern facing windows with overhangs, a single point mini-split heat pump and electric resistance heaters, and a balanced energy recovery ventilator (ERV). The house was instrumented with sub-metering on all major electrical circuits, temperature and humidity measurements in each room, domestic hot water consumption, and recovery efficiency of the ERV. The energy performance was documented and compared to modeled predictions, and the thermal comfort performance of the heat pump was assessed.

Research Organization:
IBACOS, Inc., Pittsburgh, PA (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B) (Building America)
DOE Contract Number:
AC36-08GO28308; KNDJ-0-40341-02
OSTI ID:
1219800
Report Number(s):
DOE/GO-102012-3489; 5973
Country of Publication:
United States
Language:
English