Title: Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer.

Technical Report ·
DOI:https://doi.org/10.2172/1213303· OSTI ID:1213303
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1213303
Report Number(s):
SAND-2015-7121R; 603186
Country of Publication:
United States
Language:
English

Similar Records

Adaptation of polytec laser interferometer to ultrasonic NDE applications
Technical Report · Sun Dec 01 00:00:00 EST 1991 · OSTI ID:1213303

Adaptation of polytec laser interferometer to ultrasonic NDE applications
Technical Report · Sun Dec 01 00:00:00 EST 1991 · OSTI ID:1213303

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers
Journal Article · Tue Jun 28 00:00:00 EDT 2016 · AIP Conference Proceedings · OSTI ID:1213303

Related Subjects