skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Saltstone 1QCY15 TCLP Toxicity and UTS Results

Abstract

A Saltstone Disposal Facility (SDF) waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the first quarter of calendar year 2015 (1QCY15). After a 28 day cure, a sample of the SDF waste form was collected, and shipped to a certified laboratory for Toxic Characteristic and Universal Treatment Standards (UTS) analysis. The metals analysis is performed using the Toxic Characteristic Leaching Procedure (TCLP). The 1QCY15 saltstone sample results meet South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents (UHC).

Authors:
 [1]
  1. Savannah River Site (SRS), Aiken, SC (United States)
Publication Date:
Research Org.:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1204366
Report Number(s):
SRNL-STI-2015-00264
DOE Contract Number:  
DE-AC09-08SR22470
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English

Citation Formats

Miller, D. Saltstone 1QCY15 TCLP Toxicity and UTS Results. United States: N. p., 2015. Web. doi:10.2172/1204366.
Miller, D. Saltstone 1QCY15 TCLP Toxicity and UTS Results. United States. https://doi.org/10.2172/1204366
Miller, D. 2015. "Saltstone 1QCY15 TCLP Toxicity and UTS Results". United States. https://doi.org/10.2172/1204366. https://www.osti.gov/servlets/purl/1204366.
@article{osti_1204366,
title = {Saltstone 1QCY15 TCLP Toxicity and UTS Results},
author = {Miller, D.},
abstractNote = {A Saltstone Disposal Facility (SDF) waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the first quarter of calendar year 2015 (1QCY15). After a 28 day cure, a sample of the SDF waste form was collected, and shipped to a certified laboratory for Toxic Characteristic and Universal Treatment Standards (UTS) analysis. The metals analysis is performed using the Toxic Characteristic Leaching Procedure (TCLP). The 1QCY15 saltstone sample results meet South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents (UHC).},
doi = {10.2172/1204366},
url = {https://www.osti.gov/biblio/1204366}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jul 29 00:00:00 EDT 2015},
month = {Wed Jul 29 00:00:00 EDT 2015}
}