Title: Full Coverage Shaped Hole Film Cooling in an Accelerating Boundary Layer with High Free-Stream Turbulence

Conference ·
OSTI ID:1187029

Full coverage shaped-hole film cooling and downstream heat transfer measurements have been acquired in the accelerating flows over a large cylindrical leading edge test surface. The shaped holes had an 8° lateral expansion angled at 30° to the surface with spanwise and streamwise spacings of 3 diameters. Measurements were conducted at four blowing ratios, two Reynolds numbers and six well documented turbulence conditions. Film cooling measurements were acquired over a four to one range in blowing ratio at the lower Reynolds number and at the two lower blowing ratios for the higher Reynolds number. The film cooling measurements were acquired at a coolant to free-stream density ratio of approximately 1.04. The flows were subjected to a low turbulence condition (Tu = 0.7%), two levels of turbulence for a smaller sized grid (Tu = 3.5%, and 7.9%), one turbulence level for a larger grid (8.1%), and two levels of turbulence generated using a mock aero-combustor (Tu = 9.3% and 13.7%). Turbulence level is shown to have a significant influence in mixing away film cooling coverage progressively as the flow develops in the streamwise direction. Effectiveness levels for the aero-combustor turbulence condition are reduced to as low as 20% of low turbulence values by the furthest downstream region. The film cooling discharge is located close to the leading edge with very thin and accelerating upstream boundary layers. Film cooling data at the lower Reynolds number, show that transitional flows have significantly improved effectiveness levels compared with turbulent flows. Downstream effectiveness levels are very similar to slot film cooling data taken at the same coolant flow rates over the same cylindrical test surface. However, slots perform significantly better in the near discharge region. These data are expected to be very useful in grounding computational predictions of full coverage shaped hole film cooling with elevated turbulence levels and acceleration. IR measurements were performed for the two lowest turbulence levels to document the spanwise variation in film cooling effectiveness and heat transfer.

Research Organization:
Univ. of North Dakota, Grand Forks, ND (United States)
Sponsoring Organization:
USDOE Office of Fossil Energy (FE), Clean Coal and Carbon Management
DOE Contract Number:
FE0004588
OSTI ID:
1187029
Report Number(s):
ASME Paper No. GT2015-42233
Resource Relation:
Conference: ASME Turbo Expo 2015, GT2015, June 15-19, 2015, Montreal, Canada
Country of Publication:
United States
Language:
English

Similar Records

Full coverage shaped-hole film cooling in an accelerating boundary layer with high freestream turbulence
Journal Article · Wed Feb 17 00:00:00 EST 2016 · Journal of Turbomachinery · OSTI ID:1187029

The effect of high free-stream turbulence on film cooling effectiveness
Journal Article · Tue Oct 01 00:00:00 EDT 1996 · Journal of Turbomachinery · OSTI ID:1187029

Stagnation Region Heat Transfer Augmentation at Very High Turbulence Levels