Title: Metastable Radioxenon Verification Laboratory (MRVL) Year-End Report

Technical Report ·
DOI:https://doi.org/10.2172/1182947· OSTI ID:1182947
 [1];  [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

This is the year end report that is due to the client. The MRVL system is designed to measure multiple radioxenon isotopes (135Xe, 133Xe, 133mXe and 133mXe) simultaneously. The system has 12 channels to load samples and make nuclear measurements. Although the MRVL system has demonstrated excellent stability in measurements of Xe-133 and Xe-135 over the year of evaluation prior to delivery, there has been concern about system stability over measurements performed on samples with orders of magnitude different radioactivity, and samples containing multiple isotopes. To address these concerns, a series of evaluation test have been performed at the end-user laboratory. The evaluation was performed in two separate phases. Phase 1 made measurements on isotopically pure Xe-133 from high radioactivity down to the system background levels of activity, addressing the potential count rate dependencies when activities change from extreme high to very low. The second phase performed measurements on samples containing multiple isotopes (Xe-135, Xe-133 and Xe-133m), and addressed concerns about the dependence of isotopic concentrations on the presence of additional isotopes. The MRVL showed a concentration dependence on the Xe-133 due to the amount of Xe-133m that was in the sample. The dependency is due to the decay of Xe-133m into Xe-133. This document focuses on the second phase and will address the analysis used to account for ingrowth of Xe-133 from Xe-133m.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1182947
Report Number(s):
PNNL-23843; NN2003000
Country of Publication:
United States
Language:
English

Similar Records

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions
Journal Article · Wed Feb 09 00:00:00 EST 2022 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1182947

Testing of the KRI-developed Silicon PIN Radioxenon Detector
Technical Report · Fri Jan 23 00:00:00 EST 2015 · OSTI ID:1182947

An evaluation of radioxenon detection techniques for use with a fluid-based concentration system
Journal Article · Tue Jun 01 00:00:00 EDT 1999 · IEEE Transactions on Nuclear Science · OSTI ID:1182947

Related Subjects