Title: 99Tc Process Monitoring System In-Lab Performance Characterization

Abstract

A 99Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The design of the new system has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant.

Authors:
 [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Publication Date:
Research Org.:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1127292
Report Number(s):
PNNL-23131; RPT-DVZ-AFRI-015
830403000
DOE Contract Number:  
AC05-76RL01830
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; process monitor; pump and treat; sensor; radiochemical; technetium; groundwater

Citation Formats

O'Hara, Matthew J., and Niver, Cynthia M. 99Tc Process Monitoring System In-Lab Performance Characterization. United States: N. p., 2014. Web. doi:10.2172/1127292.
O'Hara, Matthew J., & Niver, Cynthia M. 99Tc Process Monitoring System In-Lab Performance Characterization. United States. https://doi.org/10.2172/1127292
O'Hara, Matthew J., and Niver, Cynthia M. 2014. "99Tc Process Monitoring System In-Lab Performance Characterization". United States. https://doi.org/10.2172/1127292. https://www.osti.gov/servlets/purl/1127292.
@article{osti_1127292,
title = {99Tc Process Monitoring System In-Lab Performance Characterization},
author = {O'Hara, Matthew J. and Niver, Cynthia M.},
abstractNote = {A 99Tc Process Monitoring (Tc-Mon) System has been designed and built for deployment at the recently constructed 200 West Pump & Treat (200W P&T) Plant in the 200 West Area ZP-1 Operable Unit of the Hanford Site. The plant is operated by CH2M Hill Plateau Remediation Company (CHPRC). The Tc-Mon system was created through collaboration between Pacific Northwest National Laboratory (PNNL) and Burge Environmental, Inc. The design of the new system has been optimized based on experience from an earlier field test (2011) of a prototype system at the 200W-ZP-1 Interim Pump & Treat Plant.},
doi = {10.2172/1127292},
url = {https://www.osti.gov/biblio/1127292}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jan 01 00:00:00 EST 2014},
month = {Wed Jan 01 00:00:00 EST 2014}
}