Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1126310
- Report Number(s):
- DOE/GO-102014-4299; KNDJ-0-40341-03
- Resource Relation:
- Related Information: Work performed by IBACOS, Inc., Pittsburgh, Pennsylvania
- Country of Publication:
- United States
- Language:
- English
Similar Records
Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)
Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House
Related Subjects
RESIDENTIAL
RESIDENTIAL BUILDINGS
IBACOS
BUILDING AMERICA
FIELD TEST RESULTS
COMPUTATIONAL FLUID DYNAMICS
CFD
ROOM-TO-ROOM UNIFORMITY
MINI-SPLIT
SINGLE POINT
HVAC
FRESNO
CALIFORNIA
RETROFIT UNOCCUPIED TEST HOUSE
MODEL VALIDATION
ACCA MANUAL RS
ASHRAE STANDARD 55
OCCUPANT COMFORT
SPACE CONDITIONING
50% BUILDING AMERICA BENCHMARK
HOT MIXED-DRY
LOW AIRFLOW
Buildings