Title: Multi-Collector Inductively Coupled Plasma Mass Spectrometer – Operational Performance Report

Technical Report ·
DOI:https://doi.org/10.2172/1120795· OSTI ID:1120795

The INL made an assessment of the commercially available inductively coupled plasma mass spectrometers (ICPMS) for actinide analysis; emphasizing low detection limits for plutonium. INL scientists subsequently determined if plutonium was present on a swipe, at a 10 million atom decision level. This report describes the evaluation of ICPMS instruments and the operational testing of a new process for the dissolution, separation and analysis via ICPMS of swipes for plutonium and uranium. The swipe dissolution, plutonium and uranium isolation, separation and purification are wet chemistry methods following established procedures. The ICPMS is a commercially available multi-collector magnetic sector mass spectrometer that utilizes five ion counting detectors operating simultaneously. The instrument includes a sample introduction system allowing for sample volumes of < 1 mL to be reproducibly injected into the instrument with minimal waste of the sample solution, while maximizing the useable signal. The performance of the instrument was measured using SRM 996 (244Pu spike) at concentrations of 12 parts per quadrillion (ppq, fg/mL) and with SRM 4350B Columbia River Sediment samples spiked onto swipes at the 10 million atom level. The measured limit of detection (LOD, defined as 3s) for 239Pu is 310,000 atoms based upon the instrument blank data. The limit of quantification (LOQ defined as 10 s) for 239Pu is 105,000 atoms. The measured limit of detection for 239Pu from the SRM 4350B spiked onto a swipe was 2.7 million atoms with the limit of quantification being 9.0 million atoms.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1120795
Report Number(s):
INL/EXT-13-29351
Country of Publication:
United States
Language:
English

Similar Records

Stand Up of Uranium Capability for Swipe Analysis
Technical Report · Fri Nov 01 00:00:00 EDT 2013 · OSTI ID:1120795

Multi-collector Isotope Ratio Mass Spectrometer -- Operational Performance Report
Technical Report · Wed Dec 01 00:00:00 EST 2010 · OSTI ID:1120795

Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion
Journal Article · Fri Jul 05 00:00:00 EDT 2013 · Journal of Proteome Research, 12(7):3353-3361 · OSTI ID:1120795