A study of the effectiveness of particulate cleaning protocols on intentionally contaminated niobium surfaces
- JLAB
Particulate contamination on the surface of SRF cavities limits their performance via the enhanced generation of field-emitted electrons. Considerable efforts are expended to actively clean and avoid such contamination on niobium surfaces. The protocols in active use have been developed via feedback from cavity testing. This approach has the risk of over-conservatively ratcheting an ever increasing complexity of methods tied to particular circumstances. A complementary and perhaps helpful approach is to quantitatively assess the effectiveness of candidate methods at removing intentional representative particulate contamination. Toward this end, we developed a standardized contamination protocol using water suspensions of Nb{sub 2}O{sub 5} and SS 316 powders applied to BCP’d surfaces of standardized niobium samples yielding particle densities of order 200 particles/mm{sup 2}. From these starting conditions, controlled application of high pressure water rinse, ultrasonic cleaning, or CO{sub 2} snow jet cleaning was applied and the resulting surfaces examined via SEM/scanning EDS with particle recognition software. Results of initial parametric variations of each will be reported.
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC05-06OR23177
- OSTI ID:
- 1115730
- Report Number(s):
- JLAB-ACC-09-1073; DOE/OR/23177-1006
- Resource Relation:
- Conference: Paper compiled for SRF2009, Sept 20-25 2009, Berlin, Germany
- Country of Publication:
- United States
- Language:
- English
Similar Records
Chemical Free Surface Processing for High Gradient Superconducting RF Cavities
Standardized beamline particulate characterization analysis: Initial application to CEBAF and LCLS-II cryomodule components