Preliminary Failure Modes and Effects Analysis of the US Massive Gas Injection Disruption Mitigation System Design
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a candidate design for the ITER Disruption Mitigation System. This candidate is the Massive Gas Injection System that provides machine protection in a plasma disruption event. The FMEA was quantified with “generic” component failure rate data as well as some data calculated from operating facilities, and the failure events were ranked for their criticality to system operation.
- Research Organization:
- Idaho National Lab. (INL), Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC07-05ID14517
- OSTI ID:
- 1114573
- Report Number(s):
- INL/EXT-13-30212
- Country of Publication:
- United States
- Language:
- English
Similar Records
Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module
Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module
Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators
Technical Report
·
Tue Jun 01 00:00:00 EDT 2010
·
OSTI ID:1114573
Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module
Technical Report
·
Wed Aug 01 00:00:00 EDT 2007
·
OSTI ID:1114573
Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators
Journal Article
·
Wed Feb 01 00:00:00 EST 2012
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:1114573
+5 more