Title: A new hydrostatic leveling system developed for the Advanced Photon Source.

Conference ·
OSTI ID:10971

As a result of the calibration tests performed with the first prototype units using the new measurement principle, we believe that the described leveling method is stable and accurate to the micron level with a sufficiently large range for the expected elevation changes of the support girders used in the Advanced Photon Source (APS) storage ring. Although long-term studies with this system have not been conducted, we believe that after installation this system requires little or no servicing for long periods of time. The methods described in this paper cover only the elevation changes of individual vessels. However, changes in the tilt of a girder must also be known. Therefore, a combination of tiltmeters in conjunction with this hydrostatic level system (HLS) would be most suitable for measuring the tilt and elevation changes of the APS girders.

Research Organization:
Argonne National Lab., IL (US)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
10971
Report Number(s):
ANL/ASD/CP-97314; TRN: US0103952
Resource Relation:
Conference: 5th International Workshop on Accelerator Alignment, Argonne, IL (US), 10/13/1997--10/17/1997; Other Information: PBD: 18 Sep 1998
Country of Publication:
United States
Language:
English

Similar Records

Fundamental limits on beam stability at the Advanced Photon Source.
Conference · Thu Jun 18 00:00:00 EDT 1998 · OSTI ID:10971

Fundamental limits on beam stability at the advanced photon source
Journal Article · Thu Dec 10 00:00:00 EST 1998 · AIP Conference Proceedings · OSTI ID:10971

Fundamental limits on beam stability at the advanced photon source
Journal Article · Tue Dec 01 00:00:00 EST 1998 · AIP Conference Proceedings · OSTI ID:10971