Title: A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus

Abstract

This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

Authors:
 [1]
  1. Florida Solar Energy Center
Publication Date:
Research Org.:
Univ. of Central Florida, Orlando, FL (United States)
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE); USDOE EE Office of Building Technologies (EE-2J)
Contributing Org.:
Florida Solar Energy Center
OSTI Identifier:
1079215
Report Number(s):
DOE-FSEC-03848
81.086
DOE Contract Number:  
EE0003848
Resource Type:
Conference
Resource Relation:
Conference: ASHRAE Annual Meeting, Dallas, TX, January 30, 2013
Country of Publication:
United States
Language:
English
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; Variable Refrigerant Flow, Heat Pump, Air Conditioner, Computer Model, Heat Recovery

Citation Formats

Raustad, Richard A. A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus. United States: N. p., 2013. Web.
Raustad, Richard A. A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus. United States.
Raustad, Richard A. 2013. "A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus". United States. https://www.osti.gov/servlets/purl/1079215.
@article{osti_1079215,
title = {A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus},
author = {Raustad, Richard A.},
abstractNote = {This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.},
doi = {},
url = {https://www.osti.gov/biblio/1079215}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jan 01 00:00:00 EST 2013},
month = {Tue Jan 01 00:00:00 EST 2013}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: