Title: Near real-time response matrix calibration for 10 Hz GOFB

Conference ·
OSTI ID:1049279

The 10 Hz global orbit feedback (GOFB), for damping the trajectory perturbation ({approx}10 Hz) due to the vibrations of the triplet quadrupoles, is operational. The correction algorithm uses transfer functions between the beam position monitors and correctors obtained from the online optics model and a correction algorithm based on singular value decomposition (SVD). Recently the calibration of the transfer functions was measured using beam position measurements acquired while modulating dedicated correctors. In this report, the feedback results with model matrix and measured matrix are compared.

Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
Sponsoring Organization:
USDOE SC OFFICE OF SCIENCE (SC)
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1049279
Report Number(s):
BNL-96749-2012-CP; R&D Project: KBCH139; 18035; KB0202011; TRN: US1204449
Resource Relation:
Conference: 2012 International Particle Accelerator Conference (IPAC 2012); New Orleans, LA; 20120520 through 20120525
Country of Publication:
United States
Language:
English

Similar Records

Near real-time ORM measurements and SVD matrix generation for 10 Hz global orbit feedback in RHIC
Conference · Mon Mar 28 00:00:00 EDT 2011 · OSTI ID:1049279

Orbit response matrix measurements for 10Hz global orbit feedback in RHIC
Technical Report · Fri Oct 01 00:00:00 EDT 2010 · OSTI ID:1049279

Optimization methodology for the global 10 Hz orbit feedback in RHIC
Journal Article · Tue May 08 00:00:00 EDT 2018 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1049279