The E-lens test bench for RHIC beam-beam compensation
To compensate for the beam-beam effects from the proton-proton interactions at IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are fabricating two electron lenses that we plan to install at RHIC IR10. Before installing the e-lenses, we are setting-up the e-lens test bench to test the electron gun, collector, GS1 coil, modulator, partial control system, some instrumentation, and the application software. Some e-lens power supplies, the electronics for current measurement will also be qualified on test bench. The test bench also was designed for measuring the properties of the cathode and the profile of the beam. In this paper, we introduce the layout and elements of the e-lens test bench; and we discuss its present status towards the end of this paper.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
- Sponsoring Organization:
- USDOE SC OFFICE OF SCIENCE (SC)
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 1049275
- Report Number(s):
- BNL-96805-2012-CP; R&D Project: KBCH139; 18064; KB0202011; TRN: US1204445
- Resource Relation:
- Conference: 2012 International Particle Accelerator Conference (IPAC 2012); New Orleans, LA; 20120520 through 20120525
- Country of Publication:
- United States
- Language:
- English
Similar Records
Head-on beam-beam compensation in RHIC
The effects of the RHIC E-lenses magnetic structure layout on the proton beam trajectory