Characterization of Field Exposed Thin Film Modules: Preprint
Test arrays of thin film modules have been deployed at the Solar Energy Centre near New Delhi, India since 2002-2003. Performances of these arrays were reported by O.S. Sastry [1]. This paper reports on NREL efforts to support SEC by performing detailed characterization of selected modules from the array. Modules were selected to demonstrate both average and worst case power loss over the 8 yearsof outdoor exposure. The modules characterized included CdTe, CIS and three different types of a-Si. All but one of the a-Si types were glass-glass construction. None of the modules had edge seals. Detailed results of these tests are presented along with our conclusions about the causes of the power loss for each technology.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Solar Energy Technologies Office
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1045723
- Report Number(s):
- NREL/CP-5200-54144; TRN: US201215%%106
- Resource Relation:
- Conference: Presented at the 2012 IEEE Photovoltaic Specialists Conference, 3-8 June 2012, Austin, Texas
- Country of Publication:
- United States
- Language:
- English
Similar Records
A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building
Process R&D for CIS-Based Thin-Film PV: Annual Technical Report, January 2003--January 2004