ESD testing of the 8S actuator (u)
Conference
·
OSTI ID:1043543
- Los Alamos National Laboratory
The 8S actuator is a hot-wire initiated explosive component used to drive the W76-1 2X Acorn 1V valve. It is known to be safe from human electrostatic discharge (ESD) pin-to-pin and all pin-to-cup stimuli as well as 1 amp/1 watt safe. However low impedance (furniture) ESD stimuli applied pin-to-pin has not been evaluated. Components were tested and the results analyzed. The 8S actuator has been shown to be immune to human and severe furniture ESD, whether applied pin-to-pin or pin-to-cup.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC52-06NA25396
- OSTI ID:
- 1043543
- Report Number(s):
- LA-UR-10-08040; LA-UR-10-8040; TRN: US201214%%85
- Resource Relation:
- Conference: Tri-lab dialog meeting ; November 30, 2010 ; LLNL
- Country of Publication:
- United States
- Language:
- English
Similar Records
Electrostatic Discharge (ESD) Protection for a Laser Diode Ignited Actuator
ESD evaluation of radiation-hardened, high-reliability CMOS and MNOS ICs
ESD evaluation of radiation-hardened, high reliability CMOS and MNOS ICs
Technical Report
·
Sun Jun 01 00:00:00 EDT 2003
·
OSTI ID:1043543
ESD evaluation of radiation-hardened, high-reliability CMOS and MNOS ICs
Conference
·
Sat Jan 01 00:00:00 EST 1983
·
OSTI ID:1043543
ESD evaluation of radiation-hardened, high reliability CMOS and MNOS ICs
Technical Report
·
Wed Feb 01 00:00:00 EST 1984
·
OSTI ID:1043543