Title: SDU 6 MODELING STUDY TO SUPPORT DESIGN DEVELOPMENT

Abstract

In response to Technical Task Request (TTR) HLW-SSF-TTR-2012-0017 (1), SRNL performed modeling studies to evaluate alternative design features for the 32 million gallon Saltstone Disposal Unit (SDU) referred to as SDU 6. This initial modeling study was intended to assess the performance of major components of the structure that are most significant to the PA. Information provided by the modeling will support the development of a SDU 6 Preliminary Design Model and Recommendation Report to be written by SRR Closure and Waste Disposal Authority. Key inputs and assumptions for the modeling were provided to SRNL in SRR-SPT-2011-00113 (2). A table reiterates the base case and four sensitivity case studies requested in this reference. In general, as shown in Table 4, when compared to Vault 2 Case A, the Base Case SDU 6 design produced higher peak fluxes to the water table during the 10,000 year period of analysis but lower peak fluxes within a 15,000 to 20,000 time frame. SDU 6 will contain approximately ten times the inventory of a single Vault 2 and the SDU 6 footprint is comparable to that of a group of four Vault 2 disposal units. Therefore, the radionuclide flux from SDU 6 and thatmore » from a single Vault 2 are not directly comparable. A more direct comparison would be to compare the maximum dose obtained at the 100 m boundary from the seven SDU's that will replace the 64 FDC's analyzed in the 2009 PA. This analysis will be performed in the next set of calculations planned for SDU design evaluation. Aquifer transport and dose calculations were not intended to be part of this initial scoping study. However, results from this study do indicate that replacement of the FDC design with SDU would not yield significantly higher peak doses. If the thickness of the SDU 6 floor is increased, peak doses would not occur during the 10,000 year period of analysis.« less

Authors:
Publication Date:
Research Org.:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1039988
Report Number(s):
SRNL-STI-2012-00219
TRN: US201211%%80
DOE Contract Number:  
DE-AC09-08SR22470
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; AQUIFERS; CLOSURES; DESIGN; EVALUATION; FLOORS; PERFORMANCE; RADIOISOTOPES; RECOMMENDATIONS; SENSITIVITY; SIMULATION; THICKNESS; TRANSPORT; WASTE DISPOSAL; WATER TABLES

Citation Formats

Smith, F. SDU 6 MODELING STUDY TO SUPPORT DESIGN DEVELOPMENT. United States: N. p., 2012. Web. doi:10.2172/1039988.
Smith, F. SDU 6 MODELING STUDY TO SUPPORT DESIGN DEVELOPMENT. United States. https://doi.org/10.2172/1039988
Smith, F. 2012. "SDU 6 MODELING STUDY TO SUPPORT DESIGN DEVELOPMENT". United States. https://doi.org/10.2172/1039988. https://www.osti.gov/servlets/purl/1039988.
@article{osti_1039988,
title = {SDU 6 MODELING STUDY TO SUPPORT DESIGN DEVELOPMENT},
author = {Smith, F.},
abstractNote = {In response to Technical Task Request (TTR) HLW-SSF-TTR-2012-0017 (1), SRNL performed modeling studies to evaluate alternative design features for the 32 million gallon Saltstone Disposal Unit (SDU) referred to as SDU 6. This initial modeling study was intended to assess the performance of major components of the structure that are most significant to the PA. Information provided by the modeling will support the development of a SDU 6 Preliminary Design Model and Recommendation Report to be written by SRR Closure and Waste Disposal Authority. Key inputs and assumptions for the modeling were provided to SRNL in SRR-SPT-2011-00113 (2). A table reiterates the base case and four sensitivity case studies requested in this reference. In general, as shown in Table 4, when compared to Vault 2 Case A, the Base Case SDU 6 design produced higher peak fluxes to the water table during the 10,000 year period of analysis but lower peak fluxes within a 15,000 to 20,000 time frame. SDU 6 will contain approximately ten times the inventory of a single Vault 2 and the SDU 6 footprint is comparable to that of a group of four Vault 2 disposal units. Therefore, the radionuclide flux from SDU 6 and that from a single Vault 2 are not directly comparable. A more direct comparison would be to compare the maximum dose obtained at the 100 m boundary from the seven SDU's that will replace the 64 FDC's analyzed in the 2009 PA. This analysis will be performed in the next set of calculations planned for SDU design evaluation. Aquifer transport and dose calculations were not intended to be part of this initial scoping study. However, results from this study do indicate that replacement of the FDC design with SDU would not yield significantly higher peak doses. If the thickness of the SDU 6 floor is increased, peak doses would not occur during the 10,000 year period of analysis.},
doi = {10.2172/1039988},
url = {https://www.osti.gov/biblio/1039988}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed May 02 00:00:00 EDT 2012},
month = {Wed May 02 00:00:00 EDT 2012}
}