A Magnetic Diagnostic Code for 3D Fusion Equilibria
A synthetic magnetic diagnostics code for fusion equilibria is presented. This code calculates the response of various magnetic diagnostics to the equilibria produced by the VMEC and PIES codes. This allows for treatment of equilibria with both good nested flux surfaces and those with stochastic regions. DIAGNO v2.0 builds upon previous codes through the implementation of a virtual casing principle. The codes is validated against a vacuum shot on the Large Helical Device where the vertical field was ramped. As an exercise of the code, the diagnostic response for various equilibria are calculated on the Large Helical Device (LHD).
- Research Organization:
- Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- DE-ACO2-09CH11466
- OSTI ID:
- 1039420
- Report Number(s):
- PPPL-4648; TRN: US1202196
- Country of Publication:
- United States
- Language:
- English
Similar Records
A Magnetic Diagnostic Code for 3D Fusion Equilibria
The ITER 3D Magnetic Diagnostic Response to Applied n=3 and n=4 RMP's
STELLOPT Modeling of the 3D Diagnostic Response in ITER
Technical Report
·
Tue Mar 12 00:00:00 EDT 2013
·
OSTI ID:1039420
The ITER 3D Magnetic Diagnostic Response to Applied n=3 and n=4 RMP's
Journal Article
·
Mon Sep 01 00:00:00 EDT 2014
· Plasma Physics and Controlled Fusion
·
OSTI ID:1039420
STELLOPT Modeling of the 3D Diagnostic Response in ITER
Technical Report
·
Tue May 07 00:00:00 EDT 2013
·
OSTI ID:1039420