CDF Run-II Silicon Detector: Operations and Aging
Abstract
The CDF Run-II silicon microstrip detector has seen almost 12 fb{sup -1} of proton-antiproton collisions over the last 10 years. It has shown remarkable performance, with 80% of its channels still operating error-free, and only one of its eight layers approaching the operational limits for full depletion. The measured depletion voltage and signal-to-noise ratio of these sensors give unique information about the behavior of sensors irradiated slowly over a long period of time. Data from heavily irradiated, double-sided sensors excludes a monotonic electric field inside the sensor and is instead consistent with a doubly-peaked field that is lower in the center of the sensor and higher at the edges.
- Authors:
- Publication Date:
- Research Org.:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Org.:
- USDOE Office of Science (SC)
- OSTI Identifier:
- 1033325
- Report Number(s):
- FERMILAB-CONF-11-447-PPD
TRN: US1200323
- DOE Contract Number:
- AC02-07CH11359
- Resource Type:
- Conference
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 43 PARTICLE ACCELERATORS; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; AGING; ELECTRIC FIELDS; FERMILAB COLLIDER DETECTOR; IRRADIATION; PERFORMANCE; SENSORS; SIGNAL-TO-NOISE RATIO; SI SEMICONDUCTOR DETECTORS; SILICON; Instrumentation
Citation Formats
Stancari, Michelle, and /Fermilab. CDF Run-II Silicon Detector: Operations and Aging. United States: N. p., 2011.
Web.
Stancari, Michelle, & /Fermilab. CDF Run-II Silicon Detector: Operations and Aging. United States.
Stancari, Michelle, and /Fermilab. 2011.
"CDF Run-II Silicon Detector: Operations and Aging". United States. https://www.osti.gov/servlets/purl/1033325.
@article{osti_1033325,
title = {CDF Run-II Silicon Detector: Operations and Aging},
author = {Stancari, Michelle and /Fermilab},
abstractNote = {The CDF Run-II silicon microstrip detector has seen almost 12 fb{sup -1} of proton-antiproton collisions over the last 10 years. It has shown remarkable performance, with 80% of its channels still operating error-free, and only one of its eight layers approaching the operational limits for full depletion. The measured depletion voltage and signal-to-noise ratio of these sensors give unique information about the behavior of sensors irradiated slowly over a long period of time. Data from heavily irradiated, double-sided sensors excludes a monotonic electric field inside the sensor and is instead consistent with a doubly-peaked field that is lower in the center of the sensor and higher at the edges.},
doi = {},
url = {https://www.osti.gov/biblio/1033325},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Sep 10 00:00:00 EDT 2011},
month = {Sat Sep 10 00:00:00 EDT 2011}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.