LAr Dewar Coil Feed Frame Pipe Analysis (Structural Analysis of General Structures, SAGS)
This frame pipe analysis addresses the D0 LAr dewar Condenser tube (coil) feed pipe thermal contraction stresses and moments. The configuration is shown in PEI drawing C-32545, Rev 0, and the parameters detailed in the letter of November 20, 1989, located in appendix A. Note that all other thermal considerations for these condensing coils have been made in D0 EN 3740.512-234. The conclusion of this report is the feed lines, previously deemed appropriate without detailed analysis, have been demonstrated to be adequately designed for the intended service and require no further investigation.