RHIC electron lens test bench diagnostics
Conference
·
OSTI ID:1020949
An Electron Lens (E-Lens) system will be installed in RHIC to increase luminosity by counteracting the head-on beam-beam interaction. The proton beam collisions at the RHIC experimental locations will introduce a tune spread due to a difference of tune shifts between small and large amplitude particles. A low energy electron beam will be used to improve luminosity and lifetime of the colliding beams by reducing the betatron tune shift and spread. In preparation for the Electron Lens installation next year, a test bench facility will be used to gain experience with many sub-systems. This paper will discuss the diagnostics related to measuring the electron beam parameters.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
- Sponsoring Organization:
- DOE - OFFICE OF SCIENCE
- DOE Contract Number:
- DE-AC02-98CH10886
- OSTI ID:
- 1020949
- Report Number(s):
- BNL-95226-2011-CP; R&D Project: KBCH139; 18035; KB0202011; TRN: US1103913
- Resource Relation:
- Conference: 10th European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators (DIPAC 2011); Hamburg, Germany; 20110516 through 20110518
- Country of Publication:
- United States
- Language:
- English
Similar Records
Electron Lens in RHIC
RHIC electron lens beam transport system design considerations
Head-on beam-beam compensation with electron lenses in the RHIC.
Conference
·
Sat May 01 00:00:00 EDT 2010
· Conf.Proc.C
·
OSTI ID:1020949
RHIC electron lens beam transport system design considerations
Technical Report
·
Fri Oct 01 00:00:00 EDT 2010
·
OSTI ID:1020949
+6 more
Head-on beam-beam compensation with electron lenses in the RHIC.
Conference
·
Mon Jun 23 00:00:00 EDT 2008
·
OSTI ID:1020949
+5 more