Criticality safety for K Basins sandfilters was considered. No credible normal or off-normal scenarios were determined which could compromise criticality safety and result in a K{sub eff} {>=} 0.98. The conclusion is that, due to the physical form and isotopic distribution of the fissionable material, there is no possibility of a nuclear criticality in the sandfilter. For this reason, there is no need for a criticality alarm system for the K Basins sandfilters.