Voltages across assembly joints due to direct-strike lightning currents
- Quatro Corp., Albuquerque, NM (United States)
- Sandia National Labs., Albuquerque, NM (United States)
An extensive set of direct-strike lightning tests has been carried out on a set of facsimile assembly joints of the kinds employed in the design of nuclear weapon cases. Taken as a whole, the test hardware included all the conceptual design elements that are embodied, either singly or in combination, in any specific assembly joint incorporated into any stockpiled weapon. During the present testing, the effects of all key design parameters on the voltages developed across the interior of the joints were investigated under a range of lightning stroke current parameter values. Design parameter variations included the types and number of joint fasteners, mechanical preload, surface finish tolerance and coatings, and the material from which the joint assembly was fabricated. Variations of the simulated lightning stroke current included amplitude (30-, 100-, and 200-kA peak), rise time, and decay time. The maximum voltage observed on any of the test joints that incorporated proper metal-to-metal surface contact was 65 V. Typical response values were more on the order of 20 V. In order to assess the effect of the presence of a dielectric coating (either intentional or as a result of corrosion) between the mating surfaces of a joint, a special configuration was tested in which the mating parts of the test assembly were coated with a 1-mil-thick dielectric anodizing layer. First strokes to these test assemblies resulted in very narrow voltage spikes of amplitudes up to 900 V. The durations of these spikes were less than 0.1 {mu}s. However, beyond these initial spikes, the voltages typically had amplitudes of up to 400 V for durations of 3 to 5 {mu}s.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 10190346
- Report Number(s):
- SAND-93-0788; ON: DE95001791; BR: GB0103012
- Resource Relation:
- Other Information: PBD: Aug 1994
- Country of Publication:
- United States
- Language:
- English
Similar Records
Update Direct-Strike Lightning Environment for Stockpile-to-Target Sequence
Measured responses of internal enclosures and cables due to burnthrough penetration of weapon cases by lightning