Title: Review of Savannah River Site K Reactor inservice inspection and testing restart program

Technical Report ·
DOI:https://doi.org/10.2172/10190194· OSTI ID:10190194

Inservice inspection (ISI) and inservice testing (IST) programs are used at commercial nuclear power plants to monitor the pressure boundary integrity and operability of components in important safety-related systems. The Department of Energy (DOE) - Office of Defense Programs (DP) operates a Category A (> 20 MW thermal) production reactor at the Savannah River Site (SRS). This report represents an evaluation of the ISI and IST practices proposed for restart of SRS K Reactor as compared, where applicable, to current ISI/IST activities of commercial nuclear power facilities.

Research Organization:
EG and G Idaho, Inc., Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
10190194
Report Number(s):
EGG-MS-9869; ON: DE93001959
Resource Relation:
Other Information: PBD: Sep 1992
Country of Publication:
United States
Language:
English