Safety analysis report for packaging for the Idaho National Engineering Laboratory TRA Type 1 Shipping Container and TRA Type 2 Shipping Capsule
The TRA Type I Shipping Container and TRA Type II Shipping Capsule were designed and fabricated at the Idaho National Engineering Laboratory as special form containers for the transport of non-fissile radioisotopes and fissile radioisotopes in exempt quantities. The Type I container measures 0.75 in. outside diameter and 3.000 in long. The Type II capsule is 0.495 in. outside diameter 2.000 in. long. The container and capsule were tested and evaluated to determine their compliance with Title 49 Code of Federal Regulations 173, which governs packages for special form radioactive material. This report is based upon those tests and evaluations. The results of those tests and evaluations demonstrate the container and capsule are in full compliance with the special form shipping container regulations of 49 CFR 173.
- Research Organization:
- EG and G Idaho, Inc., Idaho Falls, ID (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC07-76ID01570
- OSTI ID:
- 10188485
- Report Number(s):
- EGG-PRP-10372; ON: DE93001918
- Resource Relation:
- Other Information: PBD: 27 Jul 1992
- Country of Publication:
- United States
- Language:
- English