Title: Precipitate hydrolysis experimental facility (PHEF): Run 64 report

Technical Report ·
DOI:https://doi.org/10.2172/10186002· OSTI ID:10186002
; ; ;  [1]
  1. Westinghouse Savannah River Co., Aiken, SC (United States). Savannah River Technology Center

The significant findings of Run 64 are: (a) Carbon dioxide was demonstrated to be an acceptable inertant for the actual hydrolysis process. However, based on the severe degradation of the tetraphenylborate (TPB) precipitate slurry stored in the Precipitate Hold Tank (PHT) at PHEF following Run 65, further evaluation of the suitability of carbon dioxide as an inertant for the long term storage of precipitate slurries is warranted. (b) Phenylboronic acid (PBA) reaction kinetics were excellent with no detectable PBA in Precipitate Hydrolysis Aqueous (PHA) product. (c) PHA product was low in biphenyl (6 mg/l), diphenylamine (13 mg/l), and total high boiling organics (22 mg/l). (d) Reproduced vacuum collapse problems encountered in DWPF (Defense Waste Processing Facility) water runs and demonstrated that the high vacuums experience during water runs could not be reproduced under normal operating conditions. (e) High benzene losses through stack and fugitive emissions were noted during Run 64. This may lead to poor decanter extraction performance long term and may be problem in DWPF, especially during long lay-ups or at low attainments. Approximately 69% of the benzene produced during Run 64 was released as benzene emissions.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
10186002
Report Number(s):
WSRC-TR-94-0161; ON: DE94019062; TRN: 94:020160
Resource Relation:
Other Information: PBD: 29 Jul 1994
Country of Publication:
United States
Language:
English