Title: Tidd PFBC hot gas filter operating experience: July 1993--April 1994

Technical Report ·
DOI:https://doi.org/10.2172/10185817· OSTI ID:10185817

The objective of this program is to evaluate the design and obtain operating experience for up to two Advanced Particle filter (APF) systems through long-term testing on a slipstream at Ohio Power Company`s Tidd Pressurized Fluidized Bed Combustion (PFBC) Demonstration Plant. Performance and reliability of commercial-scale filter modules will be monitored to aid in assessment of the readiness and economic viability of this technology for commercial PFBC applications. Operating conditions, performance of the filter, and post-operation inspection results are discussed for Test Runs 5 through 18.

Research Organization:
Ohio Power Co., Columbus, OH (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
FC21-89MC26042
OSTI ID:
10185817
Report Number(s):
DOE/MC/26042-94/C0382; CONF-9406131-34; ON: DE95000653; BR: AA0510000/AA3510100; TRN: AHC29424%%46
Resource Relation:
Conference: Coal-fired power systems: advances in IGCC and PFBC review meeting,Morgantown, WV (United States),21-23 Jun 1994; Other Information: PBD: [1994]
Country of Publication:
United States
Language:
English