Title: Integrated Low Emissions Cleanup system for direct coal fueled turbines (moving bed, fluid contactor/ceramic filter). Twenty-second quarterly status report, January--March 1993

Technical Report ·
DOI:https://doi.org/10.2172/10182078· OSTI ID:10182078

The United States Department of Energy, Morgantown Energy Research Center (DOE/METC), is sponsoring the development of direct coal-fired turbine power plants as part of their Heat Engines program. A major technical challenge remaining for the development of the direct coal-fired turbine is high-temperature combustion gas cleaning to meet environmental standards for sulfur oxides and particulate emissions, as well as to provide acceptable turbine life. The Westinghouse Electric Corporation, Science & Technology Center, is evaluating two Integrated Low Emissions Cleanup (ILEC) concepts that have been configured to meet this technical challenge: A baseline ceramic barrier filter ILEC concept, and a fluidized bed ILEC concept. These ILEC concepts simultaneously control sulfur, particulate, and alkali contaminants in the high-pressure combustion gases at turbine inlet temperatures up to 2300{degrees}F. This document reports the status of a program in the nineteenth quarter to develop this ILEC technology for direct coal-fired turbine power plants.

Research Organization:
Westinghouse Electric Corp., Pittsburgh, PA (United States). Science and Technology Center
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC21-87MC24257
OSTI ID:
10182078
Report Number(s):
DOE/MC/24257-3431; ON: DE94000457
Resource Relation:
Other Information: PBD: [1993]
Country of Publication:
United States
Language:
English