Title: Regulatory analysis for the resolution of Generic Issue 153: Loss of essential service water in LWRs

Technical Report ·
DOI:https://doi.org/10.2172/10179967· OSTI ID:10179967

In this report, the staff of the US Nuclear Regulatory Commission provides a regulatory analysis for the proposed resolution of Generic Issue 153 (GI-153), ``Loss of Essential Service Water in LWRS.`` GI-153 deals with the concerns pertaining to the reliability of essential service water (ESW) system and related problems for all light water reactors except the seven multi-unit sites addressed by GI-130. ``Essential Service Water Pump failures at Multi-Unit Sites.`` On the basis of the technical findings of a scoping study for GI-153, the staff recommends that the insights gained from the study serve as a complement to the on-going ESW performance inspection program. The staff also concludes that ESW system reliability is being addressed by various on-going regulatory programs. Therefore, the staff recommends that GI-153 should be considered ``RESOLVED.`` The need for future action(s) on ESW reliability is expected to be determined from these on-going programs.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Safety Issue Resolution
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
OSTI ID:
10179967
Report Number(s):
NUREG-1461; ON: TI93019499; TRN: 93:019173
Resource Relation:
Other Information: PBD: Aug 1993
Country of Publication:
United States
Language:
English