Radiation induced darkening of the optical elements in the Startracker camera
Optical glass flats that closely simulate the elements used in the Startracker lens designs were exposed to doses of ionizing radiation ranging from 0.44 to 1300 krad. Photometer traces determined the transmittance of the samples as a function of both wavelength and dose for wavelengths in the range 300 to 1200 nm. Cerium stabilized glasses used in the radiation stabilized Startracker system showed only a small amount of darkening for doses up to and exceeding 1 Mrad. Glasses used in the unstabilized Startracker design showed significant darkening to visible and ultra-violet spectra for doses as low as 5 krad. Plots of transmittance versus wavelength for various doses are given for each of the Startracker optical elements. Radiation induced absorption parameters that determine the radiation induced absorption coefficient are tabulated and plotted versus wavelength.
- Research Organization:
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 10177329
- Report Number(s):
- UCRL-ID-113713; ON: DE93018907; TRN: 93:019111
- Resource Relation:
- Other Information: PBD: Mar 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Transient radiation-induced absorption at 1061 nm in LiNiO[sub 3] and MgO:LiNbO[sub 3]
Design and fabrication of optical thin films for remote sensing instruments