Title: Hanford Site radionuclide national emission standards for hazardous air pollutants unregistered stack (power exhaust) source assessment

Abstract

On February 3, 1993, the US Department of Energy, Richland Operations Office received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the US Environmental Protection Agency, Region 10. The Compliance Order requires the Richland Operations Office to evaluate all radionuclide emission points at the Hanford Site to determine which are subject to continuous emission measurement requirements in 40 Code of Federal Regulations (CFR) 61, Subpart H, and to continuously measure radionuclide emissions in accordance with 40 CFR 61.93. This evaluation provides an assessment of the 39 unregistered stacks, under Westinghouse Hanford Company`s management, and their potential radionuclide emissions, i.e., emissions with no control devices in place. The evaluation also determined if the effective dose equivalent from any of these stack emissions exceeded 0.1 mrem/yr, which will require the stack to have continuous monitoring. The result of this assessment identified three stacks, 107-N, 296-P-26 and 296-P-28, as having potential emissions that would cause an effective dose equivalent greater than 0.1 mrem/yr. These stacks, as noted by 40 CFR 61.93, would require continuous monitoring.

Authors:
Publication Date:
Research Org.:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10176191
Report Number(s):
WHC-SD-EN-RPT-025
ON: DE94017323; NC: NONE; TRN: AHC29419%%16
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 4 Aug 1994
Country of Publication:
United States
Language:
English
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 29 ENERGY PLANNING, POLICY AND ECONOMY; HANFORD RESERVATION; AIR POLLUTION; RADIOACTIVE EFFLUENTS; STACK DISPOSAL; AIR QUALITY; STANDARDS; RADIATION MONITORING; POLLUTION SOURCES; DATA; 053002; 290300; ENVIRONMENT, HEALTH, AND SAFETY

Citation Formats

Davis, W E. Hanford Site radionuclide national emission standards for hazardous air pollutants unregistered stack (power exhaust) source assessment. United States: N. p., 1994. Web. doi:10.2172/10176191.
Davis, W E. Hanford Site radionuclide national emission standards for hazardous air pollutants unregistered stack (power exhaust) source assessment. United States. https://doi.org/10.2172/10176191
Davis, W E. 1994. "Hanford Site radionuclide national emission standards for hazardous air pollutants unregistered stack (power exhaust) source assessment". United States. https://doi.org/10.2172/10176191. https://www.osti.gov/servlets/purl/10176191.
@article{osti_10176191,
title = {Hanford Site radionuclide national emission standards for hazardous air pollutants unregistered stack (power exhaust) source assessment},
author = {Davis, W E},
abstractNote = {On February 3, 1993, the US Department of Energy, Richland Operations Office received a Compliance Order and Information Request from the Director of the Air and Toxics Division of the US Environmental Protection Agency, Region 10. The Compliance Order requires the Richland Operations Office to evaluate all radionuclide emission points at the Hanford Site to determine which are subject to continuous emission measurement requirements in 40 Code of Federal Regulations (CFR) 61, Subpart H, and to continuously measure radionuclide emissions in accordance with 40 CFR 61.93. This evaluation provides an assessment of the 39 unregistered stacks, under Westinghouse Hanford Company`s management, and their potential radionuclide emissions, i.e., emissions with no control devices in place. The evaluation also determined if the effective dose equivalent from any of these stack emissions exceeded 0.1 mrem/yr, which will require the stack to have continuous monitoring. The result of this assessment identified three stacks, 107-N, 296-P-26 and 296-P-28, as having potential emissions that would cause an effective dose equivalent greater than 0.1 mrem/yr. These stacks, as noted by 40 CFR 61.93, would require continuous monitoring.},
doi = {10.2172/10176191},
url = {https://www.osti.gov/biblio/10176191}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Aug 04 00:00:00 EDT 1994},
month = {Thu Aug 04 00:00:00 EDT 1994}
}